1C Server service does not start

Golovna / Troubleshooting

Great guessing for yourself. Because This information is widely available on the Internet. I shorazu shukati – gayati hour.

The information is relevant for the installation of two versions of the 1C server on one working server. My version was already running the 1C server agent: Enterprise 8.2. And after updating, even though I was running the 1C server agent: Enterprise 8.3, the 1C agent service did not start. At the end of the hour, I’ll look at the startup sequence and note that the installer installed the ports after installation, although in my case, just for 1C 8.3, the ports were previously administrated from those that the installation program installed after installation. You can do this in the Windows “Server Panel” under the section “Administration” - “Services” - “1C Server Agent: Enterprise 8.x”, going to a specific service. For example, I’ll show you that the ports are already occupied by the agent of the 1C server: Enterprise 8.1:

After updating the platform of the major version 8.3 to the new minor version, in the server agent 1C: Enterprise 8.3, as it was assigned above, the installer installed the ports for the following: "C:\Program Files\1cv8\8.3.6.2076\bin\ragent.exe" -srvc -agent -regport 1541 -port 1540 -range 1560:1591 -d "C:Program Files\1cv8\srvinfo". Therefore, I needed to change the ranges of ports that were being tested. My model has a small replacement from 1500x ports to 1400x.

For this purpose we call the server agent service. Open the Windows registry editor (command regedit in the command line, which is pressed immediately by pressing the Win buttons (the button with the windows symbol) + R). Next we look at the registry button: HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\1C:Enterprise 8.2 Server Agent. At the parameter ImagePath The port set numbers can be changed: "C:\Program Files\1cv8\8.3.6.2076\bin\ragent.exe" -srvc -agent -regport 1441 -port 1440 -range 1460:1491 -d "C:Program Files\1cv82\srvinfo"


Don't forget to start the server service.

© www.. All rights reserved. The use of texts and images from this page without the written permission of the authority is blocked. If any materials are selected from this page, it is sent to this page.

Practical for the sake of setting up work with the 1C 8 server

  1. 1. How to launch more than one 1C service for parallel work with different versions of the 1C platform 8.0, 8.1, 8.2 8.3, etc.

When installing 1C on a server, we will do the following:

If you install another version for parallel robots, the installation is similar to the following point:

We understand the sign “Install the 1C:Enterprise server 8 as a Windows service (recommended)”

My vikoristamo: sc create

The row looks like this:

sc create"<Агент сервера 1С:Предприятия 8.Х.Х.ХХХХ>"binpath="<место расположения ragent.exe>-srvc -agent -regport 1641 -port 1640 -range 1660:1591 -d \"<место расположения папки сервера 1С>""

<Агент сервера 1С:Предприятия 8.Х.Х.ХХХХ>- Specify the name of the service. The main thing is that you and those who may support the 1C server can easily identify them.

<место расположения ragent.exe>-srvc -agent -regport 1641 -port 1640 -range 1660:1691 -d \"<место расположения папки сервера 1С>

The order of service is always the same:

<место расположения ragent.exe>

Since port 1540 is already busy (since one server in the service is already installed), then we set an attack or something that suits, for example, instead:

15 41-port 15 40-range 15 60:15 91

16 41-port 16 40-range 16 60:16 91

Zamist<место расположения папки сервера 1С>We indicate the row where we plan to expand the folder with server files. I recommend not saving this folder on the C: drive, split the server disk into 2. Under the system and under the 1C server. If the registry log files take up all the space on the disk, you can easily log into the server and clean them. What cannot be said is that your registry log files will take up space on the system drive.

I enter the command:

sc create "1C:Enterprise Server Agent 8.Х.Х.ХХХХ" binpath= "\"C:\Program Files\1cv8\8.Х.Х.ХХХХ\bin\ragent.exe\" -srvc -agent -regport 1741 -port 1740 -range 1760:1591 -d "E:\1C_Bases\srvinfo_8_Х_Х_ХХХХ""

As a result, the service is removed:

If the service has not shown up, click the Update button.))))

If you change your mind, then you can quickly create a service:

sc delete "<Агент сервера 1С:Предприятия 8.Х.Х.ХХХХ>"

de<Агент сервера 1С:Предприятия 8.Х.Х.ХХХХ>- name of service

We set the remixer to the position “With system cloud recording”

Hurray, you're all ready!

  1. 2. How to restart the server?


And in this case you can clear the cache (this may be difficult in case of certain stupid behavior of 1C)

These files can only be deleted if the service is disabled.

If you have disabled the service, but the files are not visible, then you need to go to the Task manager and check it for any problems:

The end task has been revealed.

  1. 3. How can I transfer a database from a platform to a platform without losing the registry log?

After you install (div. point 1.) a new version of the server, you will need to transfer one or all databases from the streaming version of the platform (server) to the one you installed.

It’s easy to earn money: you open the power of the database on the streaming server

A necessary component of the client-server configuration of 1C older versions: the 1C server agent service is an integral module that is included in the delivery of the server software package and functions like a service of the Windows operating system.

The purpose of the service is keruvannya koristuvachami and system departments. The 1C Server Agent service may be subject to a variety of problems that may not be resolved. With these, you can easily contact for help changing the setup of the service, for which a separate interface has been provided. How to fix it if the service does not start at all.

In version 8.2, such a situation is signaled by a 1C alarm, which is accompanied by the following explanatory text: “ Troubleshooting at the time of launching the agent server service 1s enterprise 8.2».

This error occurs either during the process of installing a new 1C instance on the server, or when trying to simultaneously launch two 1C add-on servers: 8.1 and 8.2 on the same physical server. Let's take a look at the leather options.

Troubleshooting during installation

The reason for this problem is that the user does not have enough rights to install and start the Windows service. To perform such actions, you need administrator rights. The very installation of a new version of 1C and the launch of the “1C Server Agent” service must be signed under the username with administrative rights. If there is a problem, click the installation and run it again as the system administrator.

One-hour launch of two configurations

As stated above, the problem stems from the fact that 1C users have to install 1C 8.2 and save access to version 8.1. The reason for the compromise is that we tried the same services in both versions to deny instant access to one computer port. To avoid this conflict, you must re-register one of the services to another port. This can be done directly at the time of starting the service by adding the -port option to the ragent.exe -instsrvc launch command using a specific digital value.

57
It happens once, for no reason the 1C program shows us: Failure to connect to the 1C server: Enterprise The desired work process is not running. Connecting with the base is difficult. A dozen options to find solutions and solutions: ... 28
I have already written a number of articles: Adjustment and optimization of the server, cluster 8.3 Addition, restart, optimization of work processes of the cluster server, now a few reports: Cluster 1C 8.3 Right before, after... 18
Lots of people have problems with rphost.exe, of different types: rphost takes up all the memory rphost uses up the processor rphost has the same memory, and 1C is not running, but in the manager it’s on: reduce the space by 2-3 megabytes. How would I... 17
If the background COM process ends with a penalty: (Processing.XMLDataExchange.ModuleObject(15947)): Completion when the constructor is called (COMObject): -2147221005(0x800401F3): Invalid class string Required register library

© 2024 androidas.ru - All about Android