How to reinstall UTM egais without wasting data. What you need to know about the universal transport module View the curl invoice from the input terminals

Golovna / Contacts

UTM is a security program for generating information about alcoholic beverages and alcoholic beverages. Since the module does not have a graphical interface, it is necessary to integrate the UTM from the established product-object system.

This module is installed on the PC at the time of business activity. Since the organization has a number of structural divisions for wholesale and separate distribution – install at the skin warehouse part of the enterprise.

To ensure that the power does not fail during the hour of work with the UTM, it is necessary to restore upcoming recommendations:

  • UTM can be installed either independently or with extension to the territorial bodies of the Federal Service for Alcohol Regulation;
  • It is necessary to install the module as soon as technically possible;
  • Sending information from one workstation with UTM is impossible; installation on the structural part of the skin is required;
  • IP that sells beer, beer drinks and cider, install a module on one work station;
  • Before you work, you need to use an accounting system that transfers information to the installed format through UTM.

Special office

If ADAIS is evident, you can proceed before registering in a special account.

Activities in a special office:

  • open the portal and go to a special office;
  • press “Get to know the minds...” – this is necessary to verify the correctness of the minds of the access;
  • if there is a shortage of components, the system will prompt you to download and install the required distribution;
  • after checking, click “Go to the special account”;
  • In the column "Enter PIN code (GOST)" enter the password for the program;
  • click "Show certificates";
  • then open the power account window showing the KEP certificate.

Obov'yazkovimi minds for registration:

  • availability of OS Windows XP, RAM 2 GB, processor 1.9 GHz and disk storage 50 GB;
  • a software component for robots with UCEP (enhanced with a qualified electronic signature), which can be used correctly with the Internet Explorer browser version no lower than 9.0;
  • availability of the hardware key.

Before registering in a special office for alcohol consumption, the organization must:

  • mother crypto-key JaCarta with crypto-provider SE PKI/GOST;
  • mother UKEP for the stolen connection with ЄDAIV.

Only after this, either independently or with the help of UTM, register in a special account, download programs for working with ADAIS, or modernize the merchandise system to match the technical capabilities of ADAIS.

Since the company's activity lies in the retail trade of alcoholic beverages, it will also require the presence of a JaCarta hardware crypto-key and UKEP for registration before registering in a special account. After this, UTM is installed on the PC and POS terminals are purchased in cooperation with the module, which operate scanners to read stamps.

Features of the installation

To register in a special account and further work on the official website of ADAIS egais.ru two installation files: For work with or without an Internet connection.

After obtaining the required module, the next step is immediately:

  • check that the current hour and date are set on the PC;
  • to enable cloud recording control, press “Win+X” - “Control Panel” and uncheck the icon from the “Enable cloud recording control” parameter;
  • turn on the anti-virus program;
  • to avoid the pressure of Windows + X - Control Panel - Administrative Tools - Services - Windows;
  • All items except the key and certificate are taken away;
  • on JaCarta there is only one GOST and RSA key;
  • then press RMB for the distribution, select “Vlastivosti” - “Zagalni” - “Rozblokuvati”;
  • After RMB, the module distribution installation file is launched by selecting the “Run as administrator” menu.

Finally, you will be able to select connections, generate an RSA key, and secure the transport module.

Connections to ADAIS include upcoming stages:

  • recording a certified qualified electronic signature on the certificate key;
  • Login to your account on the official website of ADAIS.

RSA key generation

  • click in a special account for a certificate;
  • press "Remove key";
  • Select the desired item from the list that opens.

After creating the key, you can work with the module.

With Internet connection

When the universal transport module is installed, the koristuvach operates as follows:

  • right-click on the saved file under the administrator name;
  • in support of the installation of a universal transport module;
  • select installation folder;
  • select folder under shortcut;
  • click on the "Next" button;
  • select an additional assigned task (create a shortcut on the desktop);
  • pressing on "Installation";
  • Click on the “Finish” button to display a dialog box.

Next, a device with a certificate for ADAIS is inserted into the PC’s USB port, and in the dialog box after installation, a standard PIN code without spaces, JaCarta and Rutoken carriers is indicated.

After this, you need to click “Search”, check the “Victory certificate with code” icon and click “Next”. A new dialog window will open. New settings must be configured for access to the Internet. When you enter the correct data, a green check mark will appear in the box.

Once the installation has been successfully completed, click “Next”, open the browser and check that the transport module has been installed correctly. If the settings are correct, a window will open with the UTM, the term of the certificate, the changeSet and the number of the folded program.

Without connection

The UTM installation algorithm includes the following steps:

  • launching the module distribution package as an administrator;
  • completion of installation;
  • Enter the PIN of the Koristuvach.

Then we start the services of the transport module, and also check the correctness of its robot. If configured correctly, a window will open with the UTM version, storage number and shangeSet identifier. This means that the installation of the transport module is correct.

reporting instructions

The module, issued by the Federal Service for Regulation of the Alcohol Market, does not have a graphical interface.

Detailed instructions for installation and operation of the transport module include the following steps:

  • in a special ADAIS account, click on “Transport module”, enter the email address, click on the “Add” button;
  • transfer the distribution to a hard drive;
  • press “Next” to install the module;
  • select a folder and click on the “Next” button;
  • choose a location for creating a shortcut;
  • “Dali” is pressed again;
  • press the "Install" button;
  • indicate that the installation is complete;
  • click on the “Finish” button;
  • After this, enter the PIN for the JaCarta hardware key (by default, it consists of eight units);
  • press the "Search" button;
  • check the box next to the “Vikorist certificate” row;
  • emboss “Dali”;
  • enter PIN for GOST (the combination consists of 0987654321);
  • press the "Search" button.

The system automatically completes the installation and installation of the transport terminal and starts the launch via ADAIS.

How to verify the robot

Checking the correctness of the transport module's operation is completed after entering the address and access created during the time of setting up the store in the address bar of the browser. If the module is installed correctly, after entering localhost:8080, information about the version of the transport module is displayed in the window.

The presence of this tab indicates that the transport module is either running or not running. Also be sure to check if you are inserting a JaCarta device into a USB port.

The module is launched in the following ways:

  • on the notification panel: behind the coat of arms icon, right-click “Run”;
  • combination Win+X - Control Panel - Administration - Services, then you need to find Transport or Transport-Updater, select the necessary one and click the Run button.

Ensure that the track is firmly rolled, so that it takes an hour to start the transport module. Once UTM works correctly, it is recommended to check the configuration of the browser itself.

In some cases, manual installation is required, such as:

  • know the “Transport”, “Control Module” and “Monitoring” services on the PC;
  • run them as administrator;
  • If the services are not active, the power is supplied through Win+X - Control Panel - Administration - Services, find the necessary items and launch the mouse with the right button.

Then the functionality of the universal transport module is checked by entering “localhost:8080” in the address bar of the browser.

Adjusted and updated

Connect the UTM in the “Administration” section, pressing the buttons “Adjustment of nomenclature” and “Adjustment of exchange with ADAIS” and inserting a symbol in the phrase “Alcoholic products”.

  1. In the “Date of work with ADAIS” field, the date of formation in the register of separate trade of alcoholic beverages is set. Call for the date to be robbed first of all the current fate.
  2. In the menu “Date of cob sale in ADAIS” the date is set on which to enter the brand code when registering a separate sale of goods that contain alcohol.
  3. At the list of accounting programs, click the “Create” button and enter the necessary data about the UTM.

Clients can select the exchange format.

The transport module is automatically updated for all customers at any time. During this period, most computer users run anti-virus programs and firewalls on their PCs, through which UTM updates may be incorrect and the module will stop working. The documentation base of the old module is being deleted; it is recommended that users save the database and update the UTM version manually. For whom:

  • screw up the transport service;
  • launch the file StopDaemon.bat;
  • download the UTM installation file of the remaining version from the official ADAIS website;
  • uninstall the old version;
  • install new;
  • when the window appears to allow Java, install Privacy Shield and Allow access;
  • In the dialog box, enter the PIN for the certificate, click “Search” and put a sign next to the phrase “Victory the certificate...”;
  • click on the “Next” button;
  • select “Without proxy” or enter proxy settings;
  • Enter the PIN for GOST, press the “Search” button.

After which a dialogue window will open to prompt you to update to the old version. Click “OK” and select the path to the transportDB folder. When the phrase “Installation completed successfully” appears, click on the “Next” button and check the correctness of the work.

Setting up UTM for robots via Wi-Fi is aimed lower.

To manually update UTM to a new version of the project in the immediate order:


transportDB"
3. You can view the UTM through the “video program” in Windows.
4. Install a new version of UTM from an offline distribution kit.
5. Rotate the folder transportDB in C:\UTM\transporter\
6. Start the UTM services.

2. Planned update of UTM to 2.0.3

Instructions from the planned update:

A notification appears and the agent icon begins to fade.

1. We subscribe to UTM services for additional shortcuts to the UTM services.
2. Creating database archives. For this you need to copy the folder from the UTM database " transportDB" in another place. For Promovchannyam, the folder is listed at the current address: C:\UTM\transporter\transportDB


2. After notification about the availability of an update, the “Install update” menu item will be available.

3. During the update process, the transport agent icon begins to turn around.

You can check the installed update version on the UTM home page at http://localhost:8080/


If the update did not take place as planned, follow the manual update procedure to step 1 of the instructions.

3. The UTM Agent icon does not appear.

Solution: It is necessary to change the agent conf (UTM/agent/conf/agent.properties) from C:/Windows/SysWOW64/jcPKCS11-2.dll to C:/Windows/System32/jcPKCS11-2.dll

4. JaCarta blocking CKR_FUNCTION_FAILED

Actions for the most serious problem:

1. For 64-bit system to the folder //Windows/SysWOW64
For 32-bit system to the folder //Windows/System32
Copy library libtranscrypt.dll

2. Change transport service parameters in file C:/UTM/transporter/conf/transport.properties

For a 64-bit system on:
rsa.library.path=C:\Windows\SysWOW64\asepkcs.dll
gost.library.path=C:\Windows\SysWOW64\libtranscrypt.dll

For a 32-bit system on:

gost.library.path=C:\Windows\System32\libtranscrypt.dll

3. Change the parameters of the updater service in the file C:/UTM/updater/conf/transport.properties

4. Change the parameters of the monitoring service in the file C:/UTM/monitoring/conf/transport.properties
For a 64-bit system on:
rsa.library.path=C:\Windows\SysWow64\asepkcs.dll For a 32-bit system on:
rsa.library.path=C:\Windows\System32\asepkcs.dll

5. Launch UTM.

The first stage of working with ADAIS for business involves choosing a browser: Internet Explorer 8 or Google Chrome. For the other option, you need to install the CORS extension. The next step is to check that the transport module is functioning, then insert into the browser the access address to the UTM, which was specified at the time of installing the module on the organization’s PC. Information from the ADAIS website about the UTM version will appear on the screen upon successful connection.

If you have received notifications about those who do not have access to the system, you must:

  1. For Google Chrome, re-enable the extension (click and plug in) and check the settings;
  2. For Internet Explorer, go to the “Security” section, select “Modern”, activate access to your data outside the domain and restart the laptop to start the update;
  3. Find the transport.properties file on your PC, run Notepad and write the star symbol (*) in the row: access.control.allow.origin=. Save the document and restart the transport module.

It is important to remember that the UTM does not operate without the update module, so for ease of reference, place the label on a visible place on the desktop.

The final stage will be the work with invoices, which may have a problem: the store administrator does not download the documentation that the postal manager sent.

There are three reasons why the situation with work in ADAIS was given to Vinikla:

  • The director (postalnik) has entered the incorrect FSRAR ID, which is the number of the point of sale in the system;
  • Please accept the updated transport module as a result of an invoice that has not yet been processed automatically;
  • The store administrator stopped the other work program and cleared the documentation list.

If the phrases “WayBill” and “FORMBREGINFO” appear on the monitor when the invoice is validated, you need to contact technical support and report the problem.

The list of problems that arise when working with a transport module

Can't open the module because the data can't be found in the program? The reason may lie in the blocked connection of the UTM address for EDAIS or other add-ons.

To get started, find out that JaCarta is available on your PC with the transport module installed.

Try to open the UTM dekilcom in ways, for example, through the additional menu in the lower left corner of the desktop, where you will find the module icon and click on it to select the required page, or you can do it through the “Control Panel” and “Hell” sections Ministry", and in the section "Services" Find out the row: Transport-Updater, which is launched by two clicks on the mouse.

How to fix a problem that occurred while working with ADAIS:

  1. Turn on the Windows firewall and antivirus program and allow them to have configured connections for the address 127.0.0.1;
  2. If the port is being used by another program, then close it and renew the settings for communication with the transport module;
  3. We have reconnected so that the port is not detected by the program, but the transport module has not been requested, then it is necessary to reinstall it.

You may also encounter the error “Wait for time is expired” and “ERROR es.programador.transport.h.e” if the Internet speed is low, so it is recommended to change your provider or move your computer to a point where Internet speed is lower.

Upgrading the remaining version of the transport module

In early 2017, the module was updated in automatic mode, which caused a problem in the system displaying information about those whose licenses were expired in the organization. This lag is explained by the fact that UTM now automatically controls whether entrepreneurs have an active license.

To correct the problem, read the data about your point of sale on the official website of the FSRAR in the section “State information register of licenses” and if you find data that does not correspond to functionality, go to M RU as a wholesaler or licensing authority of the subject as an entrepreneur who trades in razdrib.

After confirming the information from the financial services, fill out a request with a problem in your personal account.

When recording information about the surplus, the system displays the error “java.lang.OutOfMemoryError: Java heap space.” it is necessary to work out the following steps:

  1. In the "Control Panel" section, click on the "Java" item and in the "Runtime Parameters" column, select "Xms1024m";
  2. Go to the registry, find the transport service in order to enter: - JvmMs 500 - JvmMx 1000;
  3. Restart the system and computer to update the data.

Three reasons to restart your RSA certificate

If you find such warnings on your laptop screen, then update your point of sale certificate on the ADAIS website:

  • The conveyor curtains say “shouldn't create SOAP message due to exception: 100% 100% 100% 1000 pcs.
  • Pardon Vikonannya Zavdan es.programador.transport.updater.i:java.io.IOException:org.xml.sax.SAXParseException; Premature end of file.at";
  • Vloglog shows "caused by: javax.xml.stream.XMLStreamException: ParseError at :".

Problems and solutions for robots with ADAIS arise from time to time, and it is necessary to know how to solve them in a number of ways, so that there will never be one option to help two people. It is important to stay up to date with the latest versions of UTM to ensure that you are aware of changes to the EDAIS system, as well as high-speed internet, which may cause difficulties for those connected to the system.

Description

After updating to version 3.0.8, the universal transport module does not start, and the tray icon does not appear.

The UTM logs have problems with starting services.

Vbudovaniy Zahisnik Windows ( Microsoft Security Essentials ) blocks the launch of universal transport module (UTM) services.

To solve the problem, you need to add the UTM files while turning off Windows Security, then reinstall the UTM, previously saved the UTM database.

Select the operating system that is causing the problem:

Windows 10

1. Click the "Search" button and find "Windows Defender Security Center."

2. Go to the “Virus and Threat Protection” tab


3. Find the “Bugs” section and click “Add or remove bugs”


4. Select the route to the UTM folder. As a rule, the path to the offensive folder is: C:\UTM .

5. Reinstall the UTM, saving the base in advance.


Copy the folder insidetransportDB


Delete FSRAR UTM, version 2

6. Install UTM version 3.0.8, downloaded from the egais.ru account

Windows 7; 8; 8.1

1. Find it from “Windows Manager”.

2. Select the “Programs” tab and select “Parameters”.


3. Go to the “Included files and folders” tab and click “Add”. Enter the route to the UTM folder. As a rule, the path to the offensive folder is: C:\UTM .


What should you do if you receive a notification about the controller’s connection?

1. Search for "Microsoft Security Essentials".

2. Go to “Options”, select “Include files and uninstall” and click “Look”. Then select the folder from UTM and click “Save changes”.


To save the database, go to the UTM (or TT) folder - transporter-transportDB.
Copy the folder insidetransportDBon a desktop or on a daily basis

After this trace, delete UTM. To view UTM, you need to go to Start-Control Panel-Programs and Components - FSRAR UTM, version 2
Delete FSRAR UTM, version 2

3. Install UTM version 3.0.8, downloaded from the egais.ru account


© 2024 androidas.ru - All about Android